The Weight Is Incorrect or Unstable
-
Check how the weighing system is installed:
- in a four-sensor configuration, each sensor must rest on a firm, flat support, with all supports in the same plane;
- a cross-shaped platform with one central sensor must also have a firm, stable support and must not rock.
Precise leveling with a spirit level is not required. A slight incline is acceptable, but an unstable installation, rocking, or shifting supports may cause errors and unstable readings.
-
Make sure the hive does not rock and the sensors are not submerged in water.
- Remove any contact between the platform and other objects.
- Disconnect external power: an unfiltered power source may reduce measurement quality.
- Check the configured tare.
- Repeat the measurement without changing the calibration.
Danger
Do not calibrate a new device because of a single suspicious result. Use calibration after a repair or confirmed data loss: Calibrate the Scales.